100792

OBSERVED
PROBLEM

Delayed ignition of
burner.

Burner backfiring
during combustion.

Yellow flame during
burner combustion.

Flame lifting during
combustion.

Slight smoke or odor
during initial opera-
tion.

POSSIBLE
CAUSE

1. Manifold pressure is

too low.

2. Burner orifice is

clogged.

1. Burner orifice is

clogged or damaged.

2. Burner damaged.
3. Gas regulator defective.
4. Delayed ignition.

1. Not enough air.

2. Gas regulator defective.

1. Burner orifice clogged

or damaged.

2. Manifold pressure too

high/defective gas
regulator.

1. Residues from manu-

facturing processes.

TROUBLE-

SHOOTING

Continued

REMEDY

1. Contact local natural gas

company.

2. Clean burner (see

Cleaning and Mainte-
nance
, page 26) or
replace burner orifice
(see Changing Burner
Orifice,
page 34).

1. Clean burner (see

Cleaning and Mainte-
nance
, page 26) or
replace burner orifice
(see Changing Burner
Orifice,
page 34).

2. Replace burner.
3. Replace control valve.
4. See above.

1. Check burner for dirt

and debris. If found,
clean burner (see
Cleaning and Mainte-
nance
, page 26).

2. Replace control valve.

1. Clean burner (see

Cleaning and Mainte-
nance,
page 26) or
replace burner orifice
(see Changing Burner
Orifice,
page 34).

2. Replace control valve

(see Removing Control
Valve and Burner Tube,
page 32).

1. Problem will stop after a

few hours of operation.