Service procedures, Blower wiring diagram – Desa CGR50NA User Manual

Page 34

Advertising
background image

34

100792

SERVICE

PROCEDURES

Continued

Figure 26 - Orifice

Changing Burner Orifice

1. Shut off gas supply to

heater.

2. Remove lower front

access panel on heater.

3. Disconnect burner tube

from orifice holder (see
Figure 25).

4. Remove orifice holder

from burner (see Figure
25).

5. Use socket or open-end

wrench to remove the old
orifice from the orifice
holder.

6. Clean and replace orifice,

or replace with new
orifice.

7. Turn on gas to heater and

check for gas leaks. Apply
a mixture of liquid soap
and water to all joints.
Bubbles forming show a
leak. Correct all leaks at
once.

8. Replace lower front

access panel.

Figure 25 - Orifice Location (35,000 BTU/Hr Burner Shown)

Burner
Tube

Orifice
Holder

Orifice

Burner

Black Blue

Fan Switch

(Off/On/Auto)

Red

Fan

Switch

(N.O.)

Black

Red

White

Green

White

On

110/115 V.A.C.

Blower

Motor

Black

Off

Auto

BLOWER

WIRING

DIAGRAM

(For Models With

Blower Assembly)