Troubleshooting – Desa LCR26PT User Manual

Page 19

Advertising
background image

www.desatech.com

1

121255-01A

TROUbLESHOOTING

Continued

POSSIBLE CAUSE

1. Control knob not fully

pressed in

2. Control knob not pressed in

long enough

3. Equipment shutoff valve not

fully open

4. Thermocouple connection

loose at control valve

5. Pilot flame not touching

thermocouple, which allows
thermocouple to cool, caus-
ing pilot flame to go out. This
problem could be caused by
one or both of the following:

A) Low gas pressure
B) Dirty or partially clogged

ODS/pilot

6. Thermocouple damaged
7. Control valve damaged

1. B u r n e r o r i f i c e ( s ) i s

clogged

2. Inlet gas pressure is too

low

1. Manifold pressure is too

low

2. B u r n e r o r i f i c e ( s ) i s

clogged

1. Burner orifice(s) is clogged

or damaged

2. Burner damaged
3. Gas regulator defective

1. Plaque damaged
2. Inlet gas pressure is too

low

3. Control knob set between

locked positions

1. Residues from manufactur-

ing processes

1. Metal expanding while

heating or contracting while
cooling

REMEDY

1. Press in control knob fully

2. After ODS/pilot lights, keep

control knob pressed in 30
seconds

3. Fully open equipment shut-

off valve

4. Hand tighten until snug,

then tighten 1/4 turn more

5. A) Contact local natural or

propane/LP gas company

B) Clean ODS/pilot (see

Cleaning, page 16) or re-
place ODS/pilot assembly

6. Replace pilot assembly
7. Replace control valve

1. Clean burner orifice(s)

(see Cleaning, page 16) or
replace burner orifice(s)

2. Contact local natural or

propane/LP gas company

1. Contact local natural or

propane/LP gas company

2. Clean burner orifice(s)

(see Cleaning, page 16) or
replace burner orifice(s)

1. Clean burner orifice(s)

(see Cleaning, page 16) or
replace burner orifice(s)

2. Replace burner
3. Replace gas regulator

1. Replace burner
2. Contact local natural or

propane/LP gas company

3. Turn control knob until it

locks at desired setting

1. Problem will stop after a few

hours of operation

1. This is normal with most

heaters. If noise is exces-
sive, contact qualified ser-
vice person

OBSERvED PROBLEM

ODS/pilot lights but flame
goes out when control knob
is released

Burner(s) does not light after
ODS/pilot is lit

Delayed ignition of burner(s)

Burner backfiring during
combustion

Burner plaque(s) does not
glow

Slight smoke or odor during
initial operation

Heater produces a clicking/
ticking noise just after burner
is lit or shut off

Advertising
This manual is related to the following products: