ventilation Air From Outdoors
Provide extra fresh air by using ventilation
grills or ducts. You must provide two perma-
nent openings: one within 12" (30.5 cm) of
the ceiling and one within 12" (30.5 cm) of
the floor. Connect these items directly to the
outdoors or spaces open to the outdoors.
These spaces include attics and crawl
spaces. Follow the National Fuel Gas Code,
ANSI Z223.1/NFPA 54, Section 5.3, Air for
Combustion and Ventilation
for required size
of ventilation grills or ducts.
IMPORTANT: Do not provide openings for
inlet or outlet air into attic if attic has a thermo-
stat-controlled power vent. Heated air entering
the attic will activate the power vent.

AIR FOR COMbUSTION

AND VENTILATION

Continued

Figure 2 - Ventilation Air from Inside

Building

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended

for use as supplemental heat. Use

this heater along with your primary

heating system. Do not install this

heater as your primary heat source.

If you have a central heating system,

you may run system’s circulating

blower while using heater. This will

help circulate the heat throughout

the house. In the event of a power

outage, you can use this heater as

your primary heat source.

WARNING: A qualified ser-

vice person must install heater.

Follow all local codes.

CHECK GAS TYPE

Use only the correct type of gas (natural or
propane/LP). If your gas supply is not the
correct gas type, do not install heater. Call
dealer where you bought heater for proper
type heater.

WARNING: This appliance is

equipped for either natural gas

or propane/LP gas but not both.

Gas type is indicated on the rat-

ing plate. Field conversion is not

permitted.

INSTALLATION ITEMS

Before installing heater, make sure you have
the items listed below.
• for propane/LP gas, external regulator

(supplied by installer)

• piping (check local codes)
• sealant (resistant to propane/LP gas)
• equipment shutoff valve *
• ground joint union
• sediment trap
• tee joint
• pipe wrench
• for natural gas, test gauge connection*
* A CSA design-certified equipment shutoff
valve with 1/8" NPT tap is an acceptable alter-
native to test gauge connection. The optional
CSA design-certified equipment shutoff valve
can be purchased from your dealer. See Ac-
cessories
, page 21.

Or

Remove

Door into

Adjoining

Room,

Option 3

Ventilation Grills

Into Adjoining Room,

Option 2

12"

12"

Ventilation

Grills into

Adjoining

Room,

Option 1

Outlet

Air

Ventilated

Attic

Outlet

Air

Inlet

Air

Inlet Air

Ventilated

Crawl Space

To

Crawl

Space

To Attic

Advertising
This manual is related to the following products: