1. Connect the DVR and monitor.

2. In the “Remote” setting, set the baud rate and ID the same as the “Peripheral” setting

on the video web server. Set the remote mode to RS-485.(see example below)

(REMOTE)

REMOTE MODE : RS-485

BAUD RATE : 2400

ID : 001

(MENU)

TIMER

CAMERA

RECORD

ALARM

DWELL

REMOTE

SYSTEM

EVENT

A. 1 / 4 CH DVR

B. 4 / 9 / 16 CH DMR

(MENU)

SEARCH

TIMER

RECORD

CAMERA

SYSTEM

EVENT

(SYSTEM)

:
:

REMOTE MODE : RS-485

BAUD RATE : 2400

REMOTE ID : 001

After the remote setting, connect the DVR, noting the following pins below

PIN 1, 6. RS485-A, RS485-B
Use the RS485-A & RS485-B serial communication signals to control digital units, such
as a DVR.

PIN 4, 7, 8, 9. ALARM INPUT
Use the PIN 4,7,8,9 to receive the alarm input and trigger the Video Server to send mail
to users for the a uto e-mail warning system. (Alarm1, 2 are for CH1; alarm3, 4 are for
CH2)

STEP 8: DVR REMOTE SETTING

STEP 9: PIN CONFIGURATIONS

-24-

N.O. Sensor

Pin 5

Pin 4,7, 8 or 9

GND

ALARM INPUT

A normally open contact/sensor can be connected where
Pin 5 is Ground and Pin 4, 7, 8 and 9 is the Alarm Input