Mdt2, Service diagnosis – Scotsman MDT2 User Manual

Page 19

Advertising
background image

SERVICE DIAGNOSIS

SYMPTOM

POSSIBLE CAUSE

SUGGESTED CORRECTION

Unit will not run

Blown fuse in P.C. Board

Replace fuse & check for cause of blown
fuse

No LED lights

Master switch in OFF position

Turn switch to ON position

Inoperative P.C. Board

Replace P.C. Board

Loose electrical connections

Check wiring

6th Yellow LED glows

Inoperative or dirty ice level control

Replace or clean ice level control

5th Yellow LED glows

Shortage or too soft water

See remedies for shortage of water or
install a mineral salt metering device

2nd LED glows

High head pressure

Dirty condenser. Clean

Inoperative fan motor. Replace

3rd Yellow LED blinks

Too high evap. temperature

Check and charge refrigerant system

Shortage or lack of refrigerant

3rd Yellow LED glows

Gear motor tends to run on reverse

Check gear motor capacitor

Too low gear motor rotating speed

Check rotor bearings, freezer bearings and
interior of freezer for scores. Replace
whatever is worn or damaged.

No rotation of gear motor

Check for power to drive motor (16 A
fuses)

Check for stator winding

Gear motor starts and stops

Check for correct operation of drive after a
while motor magnetic sensor

Check for correct magnetic capacity of
magnetic cylinder

Compressor cycles intermittently

Low voltage

Check circuit for overloading

Check voltage at the supply to the
building. If low, contact the power
company

Non-condensable gas in system

Purge the system

Compressor starting device with loose
wires

Check for loose wires in starting device

Low ice production

Capillary tube partially restricted

Blow charge, add new gas & drier, after
evacuating system with vacuum pump

Moisture in the system

Same as above

Low water level in the freezer

Adjust to approx 20mm below ice spout

Shortage of refrigerant

Check for leaks & recharge

Pitted or stained auger surface

Clean or replace auger

Will not dispense

Dispense motor open

Check windings

No power to dispense motor

Check harness connections from
touch free sensors to control board &
from board to motor

Control board does not work

Trace harness from touch free
sensors to PC board, jump the two
center pins, the dispense motor
should turn. If not replace the board

Open harness

Check the harness for continuity, if
any wire is open, replace the harness

Defective sensor

If the above does not prove to be a
problem, replace the sensors

MDT2

May 2002

Page 19