Technical characteristics, Sce170 – Scotsman SCE170 User Manual

Page 18

Advertising
background image

Technical Characteristics

Typical Cycle Time

•

15 - 20 minutes (time depends upon how clean unit is, plus the air and water temperatures).

Typical Harvest Ice Weight

•

1.6 to 1.8 lb. ice harvested per cycle.

Typical Low Side Pressure

•

25 PSIG just before harvest

Typical Freeze Cycle Discharge Pressure

•

Air cooled: 300 PSIG declining to 210 PSIG

•

Water cooled: 245 PSIG

Refrigerant Type / Charge

•

Air Cooled: R-404A / 17 ounces A series, 16 ounces B and Cseries

•

Water Cooled: R-404A / 9 ounces A series, 11 ounces B series and 10 ounces C series

Harvest Time:

•

Varies with ambient, usually about 1.5 - 2 minutes. Unit is in harvest until the curtain opens. The
unit may remain in harvest a maximum of 7 minutes, after which the machine returns to the freeze
cycle.

Typical Low Side Pressure, in harvest

•

85 - 100 PSIG

Typical Discharge Pressure in harvest

•

195 - 210 PSIG

Hi Pressure Cut Out

•

Cuts Out at (450 PSIG air cooled, 350 PSIG water cooled); Cuts In at 350 PSIG (air cooled)

Typical Compressor Amp Draw

•

Freeze: 6-7

•

Harvest: 7-8

Superheat

•

4-6

o

F. 10 minutes into freeze cycle. TXV is not adjustable.

Finish Freeze Time

•

4 minutes after cube size thermostat closes (indicator light on control board is ON in Timed Freeze)

Air cooled fan motor

•

16 watt rating; 1500 RPM; CW. Stops during harvest.

Compressor

•

Copeland hermetic, capacitor start, induction run.

Water Pump Motor

•

4 pole, unit bearing type.

Cube Size Control

•

Adjustable Cut In temperature as needed to obtain correct ice bridge thickness, about 8

o

F. - 10

o

F.

•

Cut In at about 31 PSIG (with normal heat load)

SCE170

June 2002

Page 18

Advertising