Sce170, Service diagnosis – Scotsman SCE170 User Manual

Page 20

Advertising
background image

Service Diagnosis

SYMPTOM

POSSIBLE CAUSE

PROBABLE FIX

Unit shuts off before bin is full.

Ice hangs up between curtain and
reservoir.

Check action of curtain, check
cube size.

Makes ice, but cubes are
mal-formed.

Water distributor is dirty.

Clean water system.

Cube size set wrong.

Adjust cube size control.

Refrigerant leak. Cubes will be
smaller or missing beginning at
the top half of the evaporator.

Locate leak, repair, replace dryer,
evacuate and weigh in nameplate
charge

Cubes/bridge too thick.

Cube size control set too cold.

Adjust cube size control.

Refrigerant leak, causing suction
line temperature to be warm,
keeping unit in the freeze cycle.

Locate leak, repair, replace dryer,
evacuate and weigh in nameplate
charge

Cubes too small, unit may stay in
harvest because ice will not push
curtain open.

Cube size control set too warm.

Adjust cube size control.

Short freeze cycle caused by
slush.

Some slush is normal. Check
purge valve for leak-thru.

Machine goes into harvest, but
ice on evaporator will not defrost -
freezes up.

Cube size set too small.

Adjust cube size control.

Cube size set too large.

Adjust cube size control.

Hot gas valve will not open.

Coil of valve open, replace.

Valve will not open, replace.

Unit freezes, but will not try to
harvest.

Cube size control will not close; to
check: Unplug water pump,
switch unit Off and then ON, in
about 2 minutes the Timed
Freeze Light on control board
should be ON

If timed freeze light does not go
ON, replace cube size control.

Timed freeze light glows, but after
4 minutes unit does not power hot
gas nor purge valves.

Replace control board

Very low on refrigerant

Check pressures

Low capacity/long freeze cycle.

Extreme hot location

Relocate the unit.

Air cooled condenser or filter dirty. Clean condenser/filter.

Cubes too big.

Adjust cube size control.

Water leak from reservoir.

Repair leak.

Float valve does not shut off.

Replace float.

Water temperature very high

Advise user

Purge valve leaks by slowly.

Replace purge valve.

Overcharged with refrigerant.

Evacuate and weigh in nameplate
charge

Hot gas valve leaks thru

Check hot gas valve. There
should be frost on line between
evaporator and valve during the
freeze cycle.

Long harvest cycle

Cube size set too large

Adjust cube size

Sticking in harvest

Check cube size or for slush

SCE170

October 1998

Page 20

Advertising