Seaward Apollo 600 User Manual
Page 26

Load Power/Current
Test Voltage:
Display Range:
Measurement Range:
Resolution:
Operating Error:
Supply Voltage, maximum
load current 16A
0.00 - 16.00A
0.50 - 16.00A
0.01A
+/-10% of reading +/- 5 digits
Lead Test
Test Voltage:
Test:
5V DC nominal
Live / Neutral checks for o/c,
s/c and crossed
Power Socket Test
Input voltage range:
195V – 253V AC
Indicates configuration of
voltage potential:-
Line potential phase to earth
Line potential phase to neutral
Line potential neutral to earth
RCD Test
Test Voltage:
Test Current:
Test Current Accuracy:
Display Range:
Measuring Range:
Resolution:
Operating Error:
230V +10%, -15%
15mA / 30mA rms sinusoidal
15mA -10% +0%, 30mA +10, -
0%
0 – 2000ms
1ms – 2000ms
1ms
±1ms
External Leakage
Test Voltage:
Display Range:
Measuring Range:
Resolution:
Operating Error:
Connected to External Adapter
0mA - 9.99mA
0.25mA - 9.99mA
0.01mA
+-5%of reading +-2 digits