How to perform Manual Tests
33
The manual tests and other options available are shown in the table
below:-
Press the appropriate key to select a test or option.
note
To store tests in memory from Manual mode you must first
select Create Appliance No., perform the tests required from
the EUT. When you have completed the required tests select
Enter Comments/Save Results, upon leaving this option the
Supernova will now store the results. Note that the Enter
Comments option is not displayed until there is something to
store. Tests carried out without appliance details being
entered will not be stored
----------MANUAL TEST SELECTION--------------
A..CREATE APPLIANCE NO.
S..CHANGE 230V/115V OP SOCKET
1..VISUAL CHECK
2..EARTH BOND TEST
3..INSULATION TEST
4..SUB LEAKAGE TEST
5..LEAKAGE TEST
6..FLASHTEST
7..TOUCH LEKAGE TEST
8..POLARITY TEST
C.ENTER COMMENTS & STORE RESULTS