Installation – Desa GA9150A User Manual

Page 2

Advertising
background image

www.desatech.com

901053-01J

2

INSTALLATION

Btu/Hr Input Btu/Hr Input

Minimum

MODEL

DESCRIPTION

Natural Gas Propane Gas Vent Opening

CVSR18

18" Single Burner

50,000

40,000

8" dia.

CPVSR18

18" Single Burner

50,000

40,000

8" dia.

CVSR24

24" Single Burner

60,000

50,000

8" dia.

CPVSR24

24" Single Burner

60,000

50,000

8" dia.

CVDR18

18" Dual Burner

55,000

45,000

8" dia.

MD18

18" Dual Burner

55,000

45,000

8" dia.

CVDR24

24" Dual Burner

65,000

55,000

8" dia.

MD24

24" Dual Burner

65,000

55,000

8" dia.

CVDR30

30" Dual Burner

70,000

60,000

8" dia.

(C)BFL(T,R) 18" Triple Burner

65,000

55,000

8" dia.

(C)BFL(T,R) 24" Triple Burner

70,000

60,000

8" dia.

FUEL PRESSURE

SPECIFICATIONS (W.C.)

Inlet

Manifold*

NG 5.5"-10.5"

3.5"

LP

11"-13"

10"

* ± .2"

CHECK GAS TYPE

You must install this Remote Ready Valve/
Pilot Kit if your gas type is propane/LP. For ad-
ditional convenience and safety, this Remote
Ready Valve/Pilot Kit can be used with natural
gas. If you are unsure of the proper applica-
tion, call dealer where you bought log set.
If the fireplace does not have a gas supply
shutoff valve, one must be installed.

CONNECTING TO GAS SUPPLY

WARNING: This appliance

requires a 1/2" NPT (National

Pipe Thread) inlet connection to

the pressure regulator.

Figure 1 - Technical Information Charts

MINIMUM FIREBOX SIZES

FRONT

BACK

MODEL

WIDTH* WIDTH** DEPTH HEIGHT

18DR/SR/MD

28"

16"

14"

18"

24DR/SR/MD 29

3

/

4

"

17"

15

1

/

2

"

18"

30DR

36"

27"

18"

18"

BFL18

28"

16"

15

1

/

2

"

18"

BFL24

30"

22"

15

1

/

2

"

18"

* Add 6" if valve/pilot is used
**At depth indicated

BURNER ORIFICE

NATURAL

PROPANE/LP

LOG SIZE

In. Num. CLR. In. Num. CLR.

18SR/DR/MD

0.129 30 Green 0.073 49

Red

24SR/DR/MD/BFL18 0.141 28 Yellow 0.086 44 Orange
30DR/BFL24

0.157 22 Yellow/ 0.089 43

Black

Blue

WARNING: A qualified service

person must connect log set to gas

supply. Follow all local codes.

CAUTION: Never connect pro-

pane/LP appliance directly to the

propane/LP supply. This appliance

requires an external regulator

(not supplied). Install the external

regulator between the heater and

propane/LP supply.

Advertising