REMOTE CONTROL OPTION
HRC100

If you are using the HRC100 remote control
option, you must first connect the leads of
the receiver to the terminal block on the gas
control (see Figure 16).
1. Connect the leads to the male fast-on

terminals marked TH and TPTH.

2. Install a 9V battery (refer to the instruc-

tions included with the HRC100).

3. Install a 9V battery into the hand held

transmitter.

4. Insert the receiver into the simulated log

control cover, with the raised cylinder fit-
ting into the hole in the cover.

5. The cover may be moved aside when op-

eration of the gas control is necessary.

Figure 16 - Connecting Wire Terminals

Control
Valve

INSTALLATION

Continued

No Optional Accessories
If you choose no remote accessories at
this time, the provided jumper wire must be
installed to the terminal block on the gas con-
trol. Connect the lead to the fast-on terminals
marked TH and TPTH (see Figure 16).

OPERATION

FOR yOUR SAFETy

REAd BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must

be lighted by hand. When lighting the pi-
lot, follow these instructions exactly.

B. BEFORE LIGHTING smell all around the ap-

pliance area for gas. Be sure to smell next
to the floor because some gas is heavier
than air and will settle on the floor.

WHAT TO dO IF yOU SMELL GAS
do not try to light any appliance.
• do not touch any electric switch; do

not use any phone in your building.

• Immediately call your gas supplier

from a neighbor’s phone. Follow the
gas supplier’s instructions.

• If you cannot reach your gas supplier,

call the fire department.

C. Use only your hand to push in or turn

the gas control knob. Never use tools.
If the knob will not push in or turn by
hand, don’t try to repair it, call a quali-
fied service technician or gas supplier.
Force or attempted repair may result in
a fire or explosion.

d. do not use this appliance if any part

has been under water. Immediately call
a qualified service technician to inspect
the appliance and to replace any part of
the control system and any gas control
which has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information

above.

2. Make sure equipment shutoff valve is fully

open.

3. Set selector switch to the OFF position.

WARNING: burner will come

on automatically within one minute

when the selector switch is in the

ON position after the pilot is lit.

Advertising