Operation – Desa WMN20A User Manual

Page 16

Advertising
background image

www.desatech.com

124002-01C

16

oPeRaTIoN

Continued

Note: The thermostat sensing bulb measures
the temperature of air near the heater cabinet.
This may not always agree with room tem-
perature (depending on housing construction,
installation location, room size, open air tem-
peratures, etc.). Frequent use of your heater will
let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1. Remove front panel (see Figure 7, page 9).
2. Follow steps 1 through 7 under Lighting

Instructions, page 15.

3. With control knob pressed in, strike match.

Hold match to pilot until pilot lights.

4. Keep control knob pressed in for 30 sec-

onds after lighting pilot. After 30 seconds,
release control knob. Now follow step 9,
under Lighting Instructions, page 15.

5. Replace front panel.

BLOWER

OPERATION

WARNING: Blower accessory

must be grounded. Blower comes

with a three-prong, grounding

plug as shown in Figure 22. The

plug is your protection against

electrical shock. Plug it into a

standard, three-hole, grounded,

outlet. If cord needs replacing,

use only a cord with a three-

prong, grounding plug.

CAUTION: Label all wires

prior to disconnection when

servicing controls. Wiring errors

can cause improper and danger-

ous operation.

CAUTION: Do not plug power

cord into electrical outlet until

installation is complete.

Figure 21 - Pilot (actual pilot may vary)

WARNING: Always operate

manual control heaters at the

locked positions. Operation

between these positions may

create a possible health hazard

if used in a poorly ventilated

room. Read owner’s manual for

complete instructions.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater
1. Turn control knob clockwise

to the

OFF position.

2. Turn off all electric power to the appliance

if service is to be performed.

3. Close equipment shutoff valve (see Figure

16, page 14).

THERMOSTAT CONTROL

OPERATION

The thermostatic control used on these
models differs from standard thermostats.
Standard thermostats simply turn on and off
the burner. The thermostat used on this heater
senses the room temperature. The thermostat
adjusts the amount of gas flow to the burner.
This increases or decreases the burner flame
height. At times the room may exceed the
set temperature. If so, the burner will shut
off. The burner will cycle back on when room
temperature drops below the set temperature.
The control knob can be set to any heat level
between 1 and 5. Selecting the 5 setting will
cause the burner to remain fully on without
modulating down in most cases.

Thermocouple

Ignitor Electrode

Pilot Burner

Grounded
Outlet

Figure 22 - Grounding Plug