Troubleshooting – Desa WMN20A User Manual

Page 19

Advertising
background image

www.desatech.com

124002-01C

19

TRoUBlesHooTING

WARNING: Turn off and unplug heater and let cool before servicing.

Only a qualified service person should service and repair heater.

CAUTION: Never use a wire, needle or similar object to clean

ODS/pilot. This can damage ODS/pilot unit.

Note: All troubleshooting items are listed in order of operation.

POSSIBLE CAUSE

1. Ignitor electrode positioned

wrong

2. Ignitor electrode broken
3. Ignitor electrode not con-

nected to ignitor cable

4. Ignitor cable pinched or

wet

5. Broken ignitor cable
6. Bad piezo ignitor (if

equipped)

7. Battery not installed in elec-

tronic ignitor (if equipped),
battery power low or battery
not installed correctly

1. Gas supply turned off or

equipment shutoff valve
closed

2. Control knob not in PILOT

position

3. Control knob not pressed in

while in PILOT position

4. Air in gas lines when in-

stalled

5. Depleted gas supply (pro-

pane/LP gas only)

6. ODS/pilot is clogged

7. Gas regulator setting is not

correct

OBSERvED PROBLEM

When ignitor button is pressed,
there is no spark at ODS/
pilot

When ignitor button is pressed,
there is spark at ODS/pilot but
no ignition

REMEDY

1. Replace pilot assembly

2. Replace pilot assembly
3. Reconnect ignitor cable

4. Free ignitor cable if pinched

by any metal or tubing.
Keep ignitor cable dry

5. Replace ignitor cable
6. Replace piezo ignitor
7. Install new alkaline battery

in electronic ignitor. Verify
battery is installed cor-
rectly

1. Turn on gas supply or open

equipment shutoff valve

2. Turn control knob to PILOT

position

3. Press in control knob while

in PILOT position

4. Continue holding down

control knob. Repeat ignit-
ing operation until air is
removed

5. Contact local propane/LP

gas company

6. Clean ODS/pilot (see Clean-

ing and Maintenance, page
18) or replace ODS/pilot
assembly

7. Replace gas regulator

Advertising
This manual is related to the following products: