Synchronized recording, Sync recording, Synchronized recording sync recording – Teac CD-RW900MKII User Manual

Page 26: 5 − recording

Advertising
background image

26

TASCAM CD-RW900MKII

5 − Recording

Sync recording

1. While recording standby mode, press the

SYNC

REC

key.

2. Set the signal detection threshold level. Use the

SYNC LEVEL option in the REC sub-menu (see

“Operation basics” on page 16).

Rotate the

MULTI JOG

dial to adjust the level. The

level can be set from -72 dB to -24 dB in 6 dB incre-

ments. The default setting is -54 dB.

Press the

MENU

key or push the

MULTI JOG

dial to

enter and return to recording standby mode.

3. Input the source signal.

Recording begins automatically when the source

signal is detected. The source signal should be high-

er than the adjusted threshold level.

S_LVL

Start of recording

level

time

Noise level

NOTE

After SYNC is set, over one second of silence which is
under the adjusted threshold level is required to start
recording automatically. Otherwise, the unit does not
begin recording even if it is detecting a signal.

When audio signal is not detected for more than five seconds,

the CD-RW900MKII automatically will stop recording and enter

record standby mode.

S_LVL

REC ready

level

time

Five seconds

NOTE

When the input level drops below the adjusted thresh-
old level for more than five seconds, recording stops
automatically and enters in recording ready mode.

3. To cancel the Sync recording mode, press the

SYNC REC

key. Recording returns to normal and

continues till you press the

STOP

key or the source

signal stops.

Pressing the

STOP

key stops recording.

The setting remains when the function is set on again.

NOTE

If you set the value so that only high-level signals trig-
ger recording, remember that the start of a piece may
not be record as in the diagram.

Recordsing starts

level

time

This part of the

track may not be

recorded

S_LVL

Also remember that when recording from an analog
source, the threshold should be set so that it is higher
than the “noise floor”. If the “noise floor” is higher
than the threshold, a false start will occur:

S_LVL

level

time

Noise is higher

than threshold

Start of track is not registered

Synchronized recording

Synchronized recording basically means that recording will

begin automatically when a signal is received, and will stop when

the signal ends.
The SYNC indicator appears on the display.

Starting playback of the source automatically starts recording on

the CD-RW900MKII if Sync function is on (see “Sync record-

ing” below) and manual record start is disabled.

Advertising