Hs-8 – Teac HS-8 Firmware V1.40 User Manual
Page 2

2
TASCAM HS-8
HS-8
3.
When the confirmation message appears, touch the OK button.
Current take list information is output to a file in the current folder of
the current project. The file is named with this format: “<current project
name>_<current folder name>_Report.csv”.
NOTE
If a file with the same name already exists, a message confirming that you
want to overwrite it will appear. Touch the OK button to overwrite that file.
ONLINE fader setting value display added
ONLINE fader setting value display has been added to the CHANNEL SETUP
screens.
CH1 SETUP screen
L/R SETUP screen
NOTE
iSince the system uses only one ONLINE fader setting, the same setting value is
linked on all channel pages and the L/R page.
iThe ONLINE fader can be operated when a TASCAM RC-HS20PD (sold sepa-
rately) is connected. It cannot be used with just the main unit. If no RC-HS20PD
is connected, the ONLINE fader setting value will be 0dB.
Metering Point switching function added
A function that allows you to set the meter display to before or after the
ONLINE fader has been added to the METER SETUP and CHANNEL SETUP
screens.
p METER SETUP screen
Metering Point
Pre Fader (default): The meters show the levels before the ONLINE fader.
Post Fader: The meters show the levels after the ONLINE fader.
p CHANNEL SETUP screens
CH1 SETUP screen
L/R SETUP screen
METER button
You can switch whether the meters show the levels before or after the
ONLINE fader. Touch the left button to have the meters show the levels
before the ONLINE fader. Touch the right button to have the meters show the
levels after the ONLINE fader.
NOTE
iBefore this function was added, the Metering Point was fixed to the Post Fader
setting. Be aware that with the addition of this function, the default Metering
Point setting is now Pre Fader.
iSince the system uses only one Metering Point setting, the same setting value is
linked on all channel pages and the L/R page.
iThe ONLINE fader can be operated when a TASCAM RC-HS20PD (sold sepa-
rately) is connected. It cannot be used with just the main unit.