Rear Panel Views

A selection of Velocity T-4200 Rear Panels in Transceiver, Receiver & Transmitter Configurations

2.6 Set-Up

2.6.1 Dry Contact Alarm

Dry contact alarms are located on the transmitter and receiver units. When there is an alarm condition
the relay is energized. An example of possible alarm causes might be over-temperature or a power
supply issue.

The dry contact alarm is a Form C contact with the following ratings:

Nominal Switching Capacity:

1 A 30 VDC

Max. Switching Power:

30 W DC