Venting installation instructions, Continued, Horizontal termination configurations – Desa (V)T32EN User Manual

Page 10

Advertising
background image

www.desatech.com

108860-01D

10

Vertical (V)

Required

Horizontal (H)

32"

36"

Vertical Pipe

(32"/36")

*40

1

/



" min. 43

1

/

4

" min.

None

30" max.

51

1

/



" min. 54

1

/

4

" min.

1 ft.

48" max.

63

1

/



" min. 66

1

/

4

" min.

 ft.

60" max.

75

1

/



" min. 78

1

/

4

" min.

3 ft.

84" max.

87

1

/



" min. 90

1

/

4

" min.

4 ft.

0' max.

Figure 15 - Horizontal Termination Configuration for Corner

Installation Using One 90° Elbow

Square

Termination

Wall

Firestop

Not to Exceed

(H) Limits

As Required for (V)

See Chart for Pipe

Section Required

45°

Elbow

90° Elbow

90° Elbow

Square

Termination

Wall

Firestop

45° Elbow

1" Minimum

*Note: Ground Floor Corner Venting

Not to Exceed

(H) Limits

Square Termination

Vertical (V) Horizontal (H)

3" Series 9" min.

17" max.

36" Series 3" min.

17" max.

Horizontal High

Wind Square

Termination

Wall Firestop

45° Elbow

CORNER AND ALTERNATE INSTALLATION
Recommended Applications:
• Corner ground floor installation

• Ground floor installation where pipe vents horizontally through

wall (over 12" horizontal pipe)

• Basement installation where one foot clearance from ground to

termination is possible

VENTING INSTALLATION

INSTRUCTIONS

Continued

Adjustable

Pipe 1" Max.

Figure 14 - Horizontal Termination Configuration for Square

and Round Terminations

45° Elbow

Wall

Firestop

Round

Termination

Cap

Exterior Portion of

Wall Firestop (Round

Termination Only)

Round Termination

(Kit HTK Shown)

Slide Ring

Over Elbow

to Complete

Connection

Horizontal termination Configurations

Figures 14 through 18 show different configurations and alterna-

tives for venting with horizontal termination. Each figure includes

a chart with critical minimum and maximum dimensions which

MUST be met. IMPORTANT: If using a venting configuration of

only horizontal venting with no vertical run, a 1/4" rise for every

12" of run toward the termination is required.

WARNING: Never run vent downward as this may

cause excessive temperatures which could cause a

fire. Operation of improperly installed and maintained

venting system could result in serious injury, property

damage or loss of life.

GROUND FLOOR INSTALLATION
Recommended Applications:
• Installation using cabinet surrounds

• Through the wall using round or square termination (up to 12"

horizontal pipe)

• NOT FOR CORNER INSTALLATION