VENTING INSTALLATION

INSTRUCTIONS

NOtICE: Read these instructions completely before

attempting installation.

These models are tested and approved for use with DESA (direct-

vent) pipe components and terminations.

The venting system must terminate on the outside of the structure

and can not be attached to a chimney or flue system serving a

separate solid fuel or gas burning appliance. A direct-vent appli-

ance must have its own venting system. DO NOT common vent

this appliance.

These models are approved to be vented either horizontally through

an outside wall or vertically through a roof or chase enclosure using

the following guidelines:
• When venting system terminates horizontally on an outside

wall, you must install a standoff if the termination cap is to be

installed directly on a combustible finish such as vinyl, wood,

stucco, etc.

• Never run the vent downward as this may cause excessive tem-

peratures which could cause a fire.

• Vent pipe air space clearances to combustibles are 1" on all sides

except on the horizontal sections, which requires 2" clearance

from the top of the pipe. Where the termination cap penetrates

a combustible wall, 1" air space clearance is required.

• Snorkel terminations are required when minimum clearance to

grade cannot be met (see Figure 16 on page 11).

• Have fireplace and selected vent components on hand to help

determine the exact measurements when elbowing or offsetting.

Always use wall firestops when penetrating walls and firestops

when penetrating ceilings or attic spaces.

• If using a venting configuration of only horizontal venting with

no vertical run, a 1/4" rise for every 12" of run toward the ter-

mination is required.

WARNING: Read all instructions completely and

thoroughly before attempting installation. Failure to

do so could result in serious injury, property damage

or loss of life.

NOtICE: Failure to follow these instructions will void

the warranty.

INStALLAtION PRECAUtIONS

• Wear gloves and safety glasses for protection

• Use extreme caution when using ladders or when on roof tops

• Be aware of electrical wiring locations in walls and ceilings

The following actions will void the warranty on your venting system:
• Installation of any damaged venting component

• Unauthorized modification of the venting system (Do not cut or

alter vent components)

• Installation of any component part not manufactured or approved

by DESA

• Installation other than as instructed by these instructions

WARNING: this gas fireplace and vent assembly

must be vented directly to the outside. The venting

system must NEVER be attached to a chimney serving

a separate solid fuel burning appliance. Each direct-

vent gas appliance must use a separate vent system.

Do not use common vent systems.

WARNING: Vent pipe air space clearances to com-

bustibles are 1" on all sides except on the horizontal

sections, which require 2" clearances from the top of

the pipe. Where the termination cap penetrates a com-

bustible wall, 1" air space clearance is required.

INSTALLATION PLANNING

There are two basic types of direct-vent installation:
• Horizontal Termination

• Vertical Termination

Horizontal Termination Installation

IMPORTANT:

Horizontal square terminations require only inner

portion of wall firestop. Horizontal installations using round ter-

mination require exterior portion of wall firestop available only in

vent kit HTK (see Figure 14, page 10).
1. Set the fireplace in its desired location and determine the route

your horizontal venting will take. Do not secure the fireplace

until all venting has been installed. Some installations require

sliding the fireplace in and out of position to make final venting

connections. Figures 14 through 18 on pages 10 and 11 show

different configurations for venting with horizontal termina-

tion that will help you decide which application best suits your

installation. Check to see if wall studs or roof rafters are in the

path of your desired venting route. If they are, you may want

to adjust the location of the fireplace.