Tri Tool 304 Tube Squaring User Manual
Page 15
Advertising
15
Model 304 Tube Squaring Machine
92-0749 : Rev. 110328
NOTE:
Continue rotating the Feed Handle clockwise until the end of the pipe is completely
machined.
Be careful not to let the tool bit(s) cut into the Saddles or the Saddle
Adapter.
Discontinue feed and allow the Cutting Head to rotate one (1) to three (3) revolu-
tions to improve the finish of the prep surface.
Rotate the Feed handle counter-clockwise to separate the Cutting Head and the
tube.
Stop the tool rotation by releasing the Motor Trigger Switch.
Rotate the Feed Handle counter-clockwise until the Cutting Head clears the tube or
pipe by at least 1/8” (3 mm) or more.
Loosen the upper Saddle by rotating the Saddle Handle Assembly to release the
tube.
Advertising