NOTE:

Engage the feed by pushing the tripper shaft in.

Monitor the cutting operation and apply cutting fluid as necessary.

The machine operation is finished when the tool holder returns home, release the
lever in order to turn off the motor.

Loosen the collet by rotating the handle up.

Remove the pipe or tubing from the Model 576AC.

The tool holder will retract automatically in 5 to 10 revolutions.

There is an audible ‘snap’ when the tool holder returns to the home position.

Observe the relationship between the pipe or tube and the tool bit.

The tool holder may be reset quickly by hand by rotating the cam feed knob
to pick up the feed slack.

It is not necessary to disengage the tripper shaft after each cutting operation.

Feed Arm

Graduation

Marks

Feed Rate

Lock Screw

Feed Rate

Adjustment

Screw