Tri Tool 576AC Sever Machine User Manual

Page 21

Advertising
background image

21

Model 576AC SEVERMASTER

TM

92-0676 : Rev. 070222

Problem: The Tool Bit is diving and the SEVERMASTER

TM

is stalling

The tool bit is dull, chipped, etc.
The tool holder adjustment slide is too loose.
The tool bit is over-extended

Problem: The pipe or tube is slipping in the collet

The clamping pressure is not tight enough.
Scale and/or other foreign material is present on the pipe or tube.
Weld seams, swelling, or bumps are preventing full contact of the collet.
Dull tool bits are causing extra force in the axial and/or radial direction.

Problem: There's a Loss of Air Power

The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.

Problem: The Tool Bit Will Not Reach the Work

Incorrect tool blocks are installed for the size of the pipe or tube being
worked on.
Incorrect tool bit is installed.

Problem: The Air Motor Will Not Start

The air power supply is shut off.
The air motor is damaged and will not run free.
The air motor needs lubrication.
Add lubrication and do not run the air motor for a few minutes, then try
running the motor.
Tap on the side of the air motor casing lightly with a piece of wood or with a
soft rubber mallet just in case the vanes may be sticking.
Sand or other foreign material may be in the vanes of the air motor.