OPERATING HEATER

NON-THERMOSTAT MODELS

FOR YOUR SAFETY READ

BEFORE LIGHTING

WARNING: If you do not fol-

low these instructions exactly,

a fire or explosion may result

causing property damage, per-

sonal injury or loss of life.

A. This appliance has a pilot which must be

lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the

appliance area for gas. Be sure to smell next

to the floor because some gas is heavier than

air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.

• Do not touch any electric switch; do not

use any phone in your building.

• Immediately call your gas supplier

from a neighborʼs phone. Follow the

gas supplierʼs instructions.

• If you cannot reach your gas supplier,

call the fire department.

C. Use only your hand to push in or turn the

gas control knob. Never use tools. If the

knob will not push in or turn by hand, donʼt

try to repair it, call a qualified service tech-

nician or gas supplier. Force or attempted

repair may result in a fire or explosion.

D. Do not use this appliance if any part has

been under water. Immediately call a

qualified service technician to inspect the

appliance and to replace any part of the

control system and any gas control which

has been under water.

LIGHTING

INSTRUCTIONS

1. STOP! Read the safety information above.

2. Make sure equipment shutoff valve is fully

open.

3. Turn control knob clockwise

to the

OFF position.

4. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information above. If you donʼt smell gas,

go to the next step.

5. Turn control knob to PILOT/IGN and

press in.

Note:

You may be running this heater for

the first time after hooking up to gas supply.

If so, you may need to press in control knob

for 30 seconds or more. This will allow air

to bleed from the gas system.

• If control knob does not pop up when

released, contact a qualified service

person or gas supplier for repairs.

6. With control knob pressed in, push down

and release ignitor button. This will light

pilot. The pilot is attached to the front of

burner. If needed, keep pressing ignitor

button until pilot lights.

If pilot does not light
• turn control knob clockwise

to

the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, page 20

• contact a qualified service person or gas

supplier for repairs

Until repairs are made, light pilot with

match. To light pilot with match, see

Manual Lighting Procedure, page 15.

7. Keep control knob pressed in for 30 seconds

after lighting pilot. After 30 seconds, release

control knob. Note: If pilot goes out, repeat

steps 3 through 7.

OFF

Ignitor Button

Control Knob

Figure 19 - Control Knob In The OFF

Position for Non-Thermostat Models

Figure 20 - Pilot

Ignitor Electrode

Pilot
Burner

Thermocouple