Inspecting heater – Desa VP26TA VN30A User Manual

Page 18

Advertising
background image

www.desatech.com

113052-01D

18

Thermocouple

Pilot Burner

Pilot Burner

Thermocouple

Blue Flame

Yellow Flame

Figure 27 - Correct Pilot Flame Pattern

Figure 28 - Incorrect Pilot Flame Pattern

Figure 29 - Correct Burner Flame Pattern

INSPECTING HEATER

Check pilot flame pattern and burner flame pat-

tern often.

PILOT FLAME PATTERN

Figure 27 shows a correct pilot flame pattern.

Figure 28 shows an incorrect pilot flame pattern.

The incorrect pilot flame is not touching the

thermocouple. This will cause the thermocouple

to cool. When the thermocouple cools, the heater

will shut down.
If pilot flame pattern is incorrect, as shown in

Figure 28
• turn heater off (see To Turn Off Gas to Ap-

pliance,

page 15 or 17, depending on your

model)

• see Troubleshooting, page 20
Note:

The pilot flame on natural gas units will

have a slight curve, but flame should be blue and

have no yellow or orange color.

Figure 30 - Incorrect Burner Flame

Pattern

BURNER FLAME PATTERN

Figure 29 shows a correct burner flame pattern. Fig-

ure 30 shows an incorrect burner flame pattern.
If burner flame pattern is incorrect, as shown in

Figure 30
• turn heater off (see To Turn Off Gas to Ap-

pliance,

page 15 or 17, depending on your

model)

• see Troubleshooting, page 20