1. STOP! Read the safety information, page

15, column 2.

2. Make sure equipment shutoff valve is fully

open.

3. Turn thermostat control knob clockwise

to the OFF position (see Figure 22

or 23 for your model).

4. Wait five minutes to clear out any gas. Then

smell for gas, including near the floor. If you

smell gas, STOP! Follow “B” in the safety

information, page 15, column 2. If you donʼt

smell gas, go to the next step.

5. Turn thermostat control knob counter-

clockwise

to the PILOT position.

Press in thermostat control knob for 5 sec-

onds (see Figure 22 or 23 for your model).

Note:

You may be running this heater for

the first time after hooking up to gas supply.

If so, you may need to press in thermostat

control knob for 30 seconds or more. This

will allow air to bleed from the gas system.

• If thermostat control knob does not pop

up when released, contact a qualified ser-

vice person or gas supplier for repairs.

6. Keep thermostat control knob pressed in while

pushing down and releasing the ignitor button.

This will light pilot. If necessary, continue to

press ignitor button until pilot lights.

If pilot does not light

• turn thermostat control knob clockwise

to the OFF position

• repeat steps 5 and 6

If pilot does not stay lit after several tries

• refer to Troubleshooting, page 20

• contact a qualified service person or gas

supplier

Until repairs are made, light pilot with

match. To light pilot with match, see

Manual Lighting Procedure, page 17.

7. Keep thermostat control knob pressed in

for 30 seconds after lighting pilot. After 30

seconds, release control knob.

Note:

If pilot goes out, repeat steps 3

through 7. This heater has a safety interlock

system. Wait one minute before lighting

pilot again.

OPERATING HEATER

Continued

8. Turn thermostat control knob counter-

clockwise

to the desired heating

level. For models, VP16TA, VN18TA,

VP26TA and VN30TA, the main burner

should light. Set control knob to any heat

level between 1 and 5 (see Figure 25). For

infrastat models, the plaque directly above

the pilot should light.

CAUTION: Do not try to ad-

just heating levels by using the

equipment shutoff valve.

Figure 22 - Control Knob In The OFF

Position, Models VP16TA, VN18TA,

VP26TA, & VN30TA

Control Knob

Ignitor Button

Figure 24 - Pilot

Figure 25 - Burner Patterns

Control

Knob

VP16TA

VN18TA

VP26TA

VN30TA

Ignitor Electrode

Pilot Burner

Thermocouple

Figure 23 - Thermostat Control Knob In The

OFF Position, Models VP16ITA & VP22ITA

1

2

3

4

OF

F

PIL

OT

Thermostat
Control Knob

Plaque Control
Knob

Ignitor
Button

Advertising