Keep alive 2-3, Configuration switch s3 2-3, Aco/alarm card (optional) 2-3 – Verilink 2100 (34-00187) Product Manual User Manual

Page 11: Configuration switch s3, Aco/alarm card (optional)

Advertising
background image

Installation

2-3

2100 CSU

Keep Alive

Positions S2-6 and S2-7 are used to select the action that
occurs upon loss of DTE signal, when the unit switches to
the Keep Alive mode on the network line. The choices are
shown in Table 2-C.

Configuration Switch S3

Switch S3 is used to set the configuration parameters listed
in the following paragraphs.

Network LBO

Positions S3-1 and S3-2 set the output signal level to the
transmit data (TXD) from the CSU to the network to the
proper line build out. These values are shown in Table 2-D.
The output level is factory set at 0 dB. It may be attenuated
by 7.5 dB, -15 dB, or -22.5 dB if operating conditions
require that it be changed. The telco should provide the
proper seting to the user. If unsure of the exact setting, then
leave it at 0 dB.

DSX Level

Positions S3-3, S3-4, and S3-5 set the DTE line interface
DSX level to one of the values shown in Table 2-E. The set-
ting should match the cable length from the CSU DTE port
to the attached equipment (cross-connect).

Line Code

Position S3-6 is used to provide AMI/B8ZS conversion from
the DTE to the facility and B8ZS/AMI conversion from the
facility to the DTE or set the line code to be transparent.

Up: Transparent

Down: Conversion

Remote Loop

Position S3-7 is used to select the signal sent to the DTE
during a remote loop.

Up: AIS to DTE

Down:Network data to DTE

ACO/Alarm Card (Optional)

The optional; ACO/alarm card monitors the alarm indica-
tors for an alarm active or an alarm clear condition and
provides closure contact points on the rear panel. The corre-
sponding front panel LED lights when an alarm condition is
detected on four different conditions:

• Network AIS (all ones)

• Network LOS (all zeros)

• Network BPVs

• DTE ones density)

The alarm card circuitry scans the status (on or off) of the
alarm indicators ten times a second (100-ms windows). The
card declares an alarm if one or more indicators are on for
100 consecutive 0.1-second samplings (10 seconds). When
this happens, the red Status indicator turns on until no alarm
conditions are detected for more than 100 consecutive 0.1-
second samplings (another 10 seconds).

Table 2-C

Keep Alive Settings

Function

S2-6

S2-7

Keep Alive is unframed all ones

Left

Left

Keep Alive is framed all ones

Left

Right

The Keep Alive signal is the acti-
vation of the line loopback.

Right

Left

Right

Right

Table 2-D

Network Line Build Out

Network LBO

S3-1

S3-2

0 dB

Down

Down

-7.5 dB

Down

Up

-15.0 dB

Up

Down

-22.5 dB

Up

Up

Table 2-E

DSX Level

DTE LBO

S3-3

S3-4

S3-5

0-133 ft

Up

Up

Down

134-266 ft

Down

Down

Up

1

2

7

6

5

4

3

NET LBO

NET LBO

DTE Le

v

el

DTE Le

v

el

DTE Le

v

el

Lin

e Co

de

Remo

te L

o

o

p

Figure 2-3

Switch S3

Up

Down

267-399 ft

Up

Down

Up

400-533 ft

Down

Up

Up

534-655 ft

Up

Up

Up

Table 2-E

DSX Level

DTE LBO

S3-3

S3-4

S3-5