Referring documents – Westermo DDW-142-485 User Manual

Page 18

Advertising
background image

18

6642-22511

Cable factory reset on DDW-142-485

It is possible to set the unit to factory default settings by using a standard Ethernet RJ-45
cable.
1. Power off the unit and disconnect all cables.
2. Connect an Ethernet cable between Ethernet ports 1 and 2. The unit needs to be

connected directly by an Ethernet cable i.e., not via a hub or switch. Use a straight cable –
not a cross-over cable, when connecting the ports.

3. Power on the unit.
4. Wait for the unit to start-up. Control that the ON LED is flashing red. The ON LED

flashing indicates that the unit is now ready to be reset to factory default. You now
have the choice to go ahead with the factory reset, or to skip factory reset and boot
as normal.

• Go ahead with factory reset:

Acknowledge that you wish to conduct the factory reset by unplugging the Ethernet
cable. The ON LED will stop flashing. This initiates the factory reset process*, and
the unit will restart with factory default settings. When the switch has booted up, the
ON LED will show a green light, and is now ready to use.

• Skip the factory reset:

To skip the factory reset process, just wait for approximately 30 seconds (after the
ON LED starts flashing RED) without unplugging the Ethernet cable. The switch will
conduct a normal boot with the existing settings.

* Note Do not power off the unit while the factory reset process is in progress.