Type tests and environmental conditions – Westermo DDW-142-485 User Manual

Page 6

Advertising
background image

6

6642-22511

Type tests and environmental conditions

Electromagnetic Compatibility
Environmental
phenomena

Basic
standard

Description

Test levels

Electrostatic discharge

EN 61000-4-2

Enclosure

Contact: ± 6 kV
Air: ± 8 kV

Fast transients

EN 61000-4-4

Power port

± 2 kV

Ethernet ports

± 2 kV

SHDSL ports

± 2 kV

RS-422/485 port

± 2 kV

Status out / Digital in

± 2 kV

Earth port

± 1 kV

Surge

EN 61000-4-5

Power port

L-L: ±0.5 kV, 2 Ω, 18 μF
L-E: ±0.5 kV, 12 Ω, 9 μF
L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±1 kV, 42 Ω, 0.5 μF

Ethernet ports
(Shielded cable)

L-E: ±2 kV, 2 Ω

SHDSL ports

L-E: ±2 kV, 42 Ω, 0.5 μF

RS-422/485 port

L-E: ±2 kV, 2 Ω

Status out / Digital in

L-E: ±2 kV, 42 Ω, 0.5 μF

EN 55024

Ethernet ports
(Shielded cable)

L-E: ± 1kV, 15 Ω

SHDSL ports

L-E: ± 1kV, 40 Ω (15 + 25 Ω)

RS-422/485 port

L-E: ± 1kV, 40 Ω (15 + 25 Ω)

Status out / Digital in

L-E: ± 1kV, 40 Ω (15 + 25 Ω)

Pulse magnetic field

EN 61000-4-9

Enclosure

300 A/m

Radiated RF immunity

EN 61000-4-3

Enclosure

20 V/m 80% AM, 1 kHz sine, 80 – 1000 MHz
12 V/m 80% AM, 1 kHz sine, 1000 – 2700 MHz

Conducted RF
immunity

EN 61000-4-6

Power port

10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz

Ethernet ports

10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz

SHDSL ports

10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz

RS-422/485 port

10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz

Status out / Digital in

10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz

Earth port

10 V, 80% AM, 1 kHz sine; 0.15 – 80 MHz

Voltage dips
and interruption

EN 61000-4-29

DC Power port

10, 20 and 5000 ms, interruption
500 ms, 30% reduction
200 ms, 60% reduction
+20 above & –20% below rated voltage

Radiated RF emission

CISPR 16-2-3
ANSI C63.4
(FCC part 15)

Enclosure

Class B
Class B

Conducted RF
emission

CISPR 16-2-1

Power port

Class B
Class B

Ethernet ports

Class B
Class B

Advertising