7

6642-22511

Electromagnetic Compatibility
Environmental
phenomena

Basic
standard

Description

Test levels

Dielectric strength

EN 60950-1

Power port to other
isolated ports

2000 Vrms 50 Hz 1 min

Ethernet ports to all
other isolated ports

1500 Vrms 50 Hz 1 min

RS-422/485 port to all
other isolated ports
SHDSL ports to all
other isolated ports
Status out / Digital
in port to all other
isolated ports

Environmental
Temperature

EN 60068-2-1
EN 60068-2-2

Operating

–40 to +70ºC (–40 to +158ºF)

Storage & Transport

–40 to +85ºC (–40 to +185ºF)

Humidity

EN 60068-2-27

Operating

5 to 95% relative humidity

Storage & Transport

5 to 95% relative humidity

Altitude

Operating

2 000 m / 70 kPa

Service life

Operating

10 years

Reliability prediction
(MTBF)

Operating

435,000 hours (MIL-HDBK- 217F2, GB, 25°C)

Vibration

IEC 60068-2-64
(random)

Operating

5 – 20 Hz: 2 m²/s³
20 – 500 Hz: – 3 dB/oct
3 axis = 3 * 30 min

Shock

IEC 60068-2-27

Operating

6 ms 1000 m/s²
6 directions, 3 shocks/direction

Bump

IEC 60068-2-27

Operating

11 ms 100 m/s²
6 directions, 100 shocks/direction

Packing
Enclosure material

EN 60950-1

Zinc (fire enclosure)

Dimension W x H x D

Without connectors

52.5 x 100 x 92 mm

With connectors

52.5 x 100 x 111 mm

Weight

0.8 kg

Degree of protection

EN 60529

Enclosure

IP 40

Cooling

Convection

Mounting

Enclosure

Horizontal on 35 mm DIN-rail

Advertising