Specifications – Westermo FD-40 User Manual

Page 7

Advertising
background image

7

6630-2242

4. Specifications

4.1 Interfaces

Power

Rated voltage

12–48 VDC

Operating voltage

9.6–57.6 VDC

Rated current

250 mA @ 12 V, 120 mA @ 24 V, 60 mA @ 48 V

Rated frequency

DC

Polarity

Reverse polarity protected

Connection

Screw terminal

Connector size

0.2–2.5 mm

2

(AWG 24–12)

Fuse

To be externally fused

PROFIBUS DP

Electrical specification

RS-485/V.11 / EN 50 170

Data rate

9.6, 19.2, 45.45, 93.75, 187.5, 500, 1 500, 3 000, 6 000
and 12 000 kbit/s

Connection

9-position D-sub (female)

Termination

External

Circuit type

TNV-1

RS-485

Electrical specification

RS-485/V.11

Data rate

1 200, 2 400, 4 800, 9 600, 14 400, 19 200 and 38 400 bit/s

Data format

7/8 data bits, no/odd/even parity, 1/2 stop bits

Connection

2-position screw terminal

Connector size

0.2 – 2.5 mm

2

(AWG 24-12)

Circuit type

TNV-1

RS-232

Electrical specification

RS-232/V.24

Data rate

1 200, 2 400, 4 800, 9 600, 14 400, 19 200 and 38 400 bit/s

Data format

7/8 data bits, no/odd/even parity, 1/2 stop bits

Connection

9-position D-sub, DTE

Circuit type

SELV