5 MAINTENANCE

- After every spraying operation, flush the pipe with clean water.
- In case of malfunction, and at any rate at the end of every season, clean the flowmeter pipe with
a special detergent.
- Do not use metal or abrasive objects for cleaning the duct.
- Do not use solvents or petrol for cleaning the external parts of the device.

5.1 Troubleshooting

FAULT

CAUSE

REMEDY

The flowmeter does not read any
value

No power supply

• Check the flowmeter wiring.

The value read by the flowmeter is
not linear or stable

Presence of turbulence or air in the
circuit

• Check the circuit

.

Tab. 2

6

TECHNICAL DATA

Description

Orion

Power supply

11 ÷ 14,5 Vdc

Max. absorption

300 mA

Min. liquid conductivity

300 µScm

Working temperature

0 °C ÷ 60 °C

+32 °F ÷ +140 °F

Storage temperature

-20 °C ÷ 60 °C

-4 °F ÷ +140 °F

Dimensions (mm)

100x200x126 / 105x114x126 (depending on the type)

Weight

886 ÷ 1650 g (depending on the type)

Tab. 3

Flowrate

Internal

passages

Impulse/Liter

(Pulses/US Gal)

l/min.

US GPM

mm

pls/l

pls/US Gal

0,3 ÷ 6

0,08 ÷ 1,6

4

6000

22710

0,5 ÷ 10

0,13 ÷ 2,6

5

6000

22710

1 ÷ 20

0,3 ÷ 5

7

3000

11355

2,5 ÷ 50

0,6 ÷ 13

10

1200

4542

5 ÷ 100

1,3 ÷ 26

14

600

2271

10 ÷ 200

2,6 ÷ 53

18,5

300

1135

20 ÷ 400

5 ÷ 106

28

150

568

30 ÷ 600

8 ÷ 158

28

100

378

Tab. 4