H3C Technologies H3C S5130 Series Switches User Manual

Page 19

Advertising
background image

12

Figure 16 Grounding through the PE wire of the AC power cord

(1) Chassis rear panel

(2) Three-wire AC power cable

NOTE:

To guarantee the grounding effect, use the grounding cable provided with the switch to connect to the
grounding strip in the equipment room as long as possible.

Installing and removing a power module
(S5130-28F-EI switch)

CAUTION:

Provide a circuit breaker for each power module and make sure the circuit breaker is off before
installation.

The S5130-28F-EI switch provides two power module slots and comes with power module slot 1 empty

and a filler panel in power module slot 2. You can install one power module, or two power modules for

redundancy. For information about power modules available for the S5130-28F-EI switch, see "Appendix
B FRUs."

When two power modules are installed, you can hot-swap a power module. To avoid device damage

and bodily injury, follow the procedures in

Figure 17

and

Figure 18

to install and replace a power

module.

Figure 17 Installation procedure

2

1