Connecting the power cord – H3C Technologies H3C S5130 Series Switches User Manual

Page 21

Advertising
background image

14

4.

Grasp the handle of the power module with one hand and pull the module part way out. Support

the module bottom with the other hand, and pull the power module slowly along the guide rails out
of the slot.

5.

Place the removed power module in an antistatic bag.

Figure 20 Removing a PSR150-A power module

Connecting the power cord

CAUTION:

Provide a circuit breaker for each power cord.

Before connecting the power cord, make sure the circuit breaker on the power cord is turned off.

Table 4 Power cord connection procedures at a glance

Switch model

Available power source

Connection procedure

reference

S5130-28S-EI

S5130-28S-PWR-EI

S5130-28TP-EI

AC power source

Connecting the switch to an AC
power source

S5130-52S-EI

S5130-28F-EI

S5130-52TP-EI

AC power source

Connecting the switch to an AC
power source

–48 V DC power source in the
equipment room

Connecting the switch to a –48
VDC power source

RPS (recommended H3C models:
RPS800-A and RPS1600-A)

Connecting the switch to an RPS

S5130-28S-HPWR-EI

S5130-28TP-PWR-EI

S5130-52S-PWR-EI

S5130-52TP-PWR-EI

AC power source

Connecting the switch to an AC
power source

H3C RPS1600-A

Connecting the switch to an RPS

The S5130-28F-EI switch provides two power module slots. The PSR150-A1, PSR150-A, and PSR150-D1

power modules are available for the S5130-28F-EI switch. The PSR150-A1 and PSR150-A power modules

Advertising