All stop (f2) command, Kalypso effects addresses – Grass Valley Switcher Products User Manual

Page 88

Advertising
background image

88

Switcher Products — Protocols Manual

Section 2 — Editor Protocol

All Stop (F2) Command

The ALL STOP command is issued to set all or a specific part of the
switcher to a known state. The command causes the following functions to
occur:

•

Any ongoing KEY MIX is stopped,

•

An ongoing AUTO TRAN (Transition) is stopped,

•

An ongoing EFF DIS (Effects Dissolve) is stopped,

•

An ongoing SEQ (Sequence) is stopped,

•

The lever arms are set to a limit,

•

The transition type is set to MIX,

•

The transition mode is set to BKGD,

•

All Keys are removed,

•

Stop Effect Run, and

•

The Source selections remain unchanged.

Kalypso Effects Addresses

Valid effects addresses used by Kalypso systems for the All Stop command
are defined in

Table 98

.

Table 97. All Stop Command

Function

Byte Count

Effects Address

Command Code

Message

Write

03

EX

F2

FF

Table 98. Kalypso Effects Addresses - All Stop Command

Effects Address

Assignment

00 PGM-PST

01

Mix/Effects 1

02

Mix/Effects 2

03

Mix/Effects 3

04

PGM-PST Secondary Partition

a

a

New effects address assignment associated with Kalypso.

05

Mix/Effects 1 Secondary Partition

a

06

Mix/Effects 2 Secondary Partition

a

07

Mix/Effects 3 Secondary Partition

a

0B

All Levels