HEIDENHAIN

31-O

SERVICE MANUAL TNC

01.09.1995

7.2

Display (blinking)

C a u s e

23

24

25

26

27

Accumulators not loaded on “open parentheses”

or

command has been

programmed, although neither the word nor the logic

accumulator has been gated or loaded.)

Incorrect type of the parentheses result different

type has been calculated in the parentheses from that
which was defined in the “open parentheses”
command, i.e. logic instead of word or vice versa.)

Conditional jump with incorrect logic accumulator
conditional jump has been programmed, although the
logic accumulator does not contain a definite value.)

Empty CASE-instruction

“END-CASE” missing

Notes: