Ceeded (range determined in mp, Operation with feed precontrol – HEIDENHAIN TNC 407 (243 020) Service Manual User Manual
Page 144

Function
MP
A
B
C
D E
F
Input
AE-6
No.
Bit
Entry Value
Feed forward control or trailing
mode
in the operating modes
"Positioning with MDI"
"Program Run / Single Block"
"Program Run / Full Sequence"
1390
0 =
feed forward control
1 =
trailing mode
0
Feed forward control
in all operating modes
X
Y
Z
IV
V
1391
0
1
2
3
4
-
-
-
-
-
02
bit not set:
control in the operating modes "Positioning with
MDI", "Program Run / Single Block" and
"Program Run / Full Sequence" according to
MP1390
bit set:
feed forward control in all operating modes
% 00000
Operation with Feed Forward Control
Function
MP
A
B
C
D E
F
Input
AE-6
No.
Bit
Entry Value
Position monitoring during
operation with feed forward control
erasable (POSITIONING ERROR)
X
Y
Z
IV
V
1410
1410.0
1410.1
1410.2
1410.3
1410.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.001 to 30 [mm]
0.0001 to 30 [mm]
3
3
3
3
3
EMERGENCY STOP
(GROSS POSITIONING ERROR)
X
Y
Z
IV
V
1420
1420.0
1420.1
1420.2
1420.3
1420.4
-
-
-
-
-
-
-
-
-
-
-
-
-
-
0.001 to 30 [mm]
0.0001 to 30 [mm]
4
4
4
4
4
16.01.95
10.2
13