SERVICE MANUAL TNC 415B/425
Page 152
Issue: 20.08.95
TNC Dialogue
Press
Key
Notes
SIGN of LIMIT X-
=
.
Press soft key,
note down the values.
LIMIT X+
=
.
(do not forget the sign!)
If MP7490 = 1, three different limits
may be active.
LIMIT Y-
=
.
In this case, note down all three
values.
LIMIT Y+
=
.
LIMIT Z-
=
.
Note down the values
(do not forget the sign!)
LIMIT Z+
=
.
LIMIT IV-
=
.
LIMIT IV+
=
.
LIMIT V-
=
.
LIMIT V+
=
.
ACTL X
.
Note down the pre-set values
ACTL Y
.
(do not forget the sign!)
ACTL Z
.
ACTL IV
.
ACTL V
.