Standard, 1 oper ation – HEIDENHAIN ND 1300 Addendum User Manual
Page 22

22
2 Operation
2.1 Oper
ation
Standard
Column Separators: Dividing Lines
Command @PRINT
1
2
3
4
5
6
7
8
9
10
11
12
|
P
|
Cir
<SP>
3
<SPS>
|
X
<SP>
68
13
14
15
16
17
18
19
20
21
22
23
24
.
1235
|
<SP>
68
.
1235
|
<SP>
0
25
26
27
28
29
30
31
32
33
34
35
36
.
0000
|
<SP>
|
<SP>
37
38
39
40
41
42
43
44
45
-
-
-
|
.
++
|
<CR>
<LF>
Character
Description
1, 3, 15, 21, 27, 33, 39, 43
Column dividing lines
2
Tolerance overall status ("P" for pass and "F" for fail)
4
Feature name (up to three characters long)
5, 10, 16, 22, 28, 34
Space
6
Feature ID (up to three characters long)
7
Trailing spaces (up to four spaces)
9
Coordinate axis (up to three characters long)
11, 17, 23, 29, 35
Sign (positive sign is not displayed)
12, 18, 24, 30, 36
1 to 9 places before the decimal point
13, 19, 25, 31, 37
Decimal point
14, 20, 26, 32, 38
0 to 6 places after the decimal point
40
Tolerance under - If tolerance passed but on the lower side of the nominal (see example)
41
Tolerance midpoint - If tolerance passed equal to the nominal (see example)
42
Tolerance over - If tolerance passed but on the upper side of the nominal (see example)
44
Carriage return
45
Line feed