Global data for probing functions, 2 pr ogr am def aults for cy cles – HEIDENHAIN iTNC 530 (34049x-08) Cycle programming User Manual
Page 62
Advertising

62
Using fixed cycles
2.2
Pr
ogr
am
def
aults
for
cy
cles
Global data for probing functions
Set-up clearance
: Distance between stylus and workpiece surface
for automated approach of the probing position
Clearance height:
The coordinate in the touch probe axis to which
the TNC traverses the touch probe between measuring points, if the
Move to clearance height
option is activated
Move to clearance height
: Select whether the TNC moves the
touch probe to the set-up clearance or clearance height between the
measuring points
Applies to all Touch Probe Cycles 4xx.