Adaptive Feed Control Software Option (AFC) 11.3

11

TNC 640 | User's Manual for DIN/ISO Programming | 3/2014

365

Select the table of AFC settings
Make optimizations if required

Note that the

<name>.H.AFC.DEP file is locked

against editing as long as the NC program

<name>.H

is running.
The TNC removes the editing lock if one of the

following functions has been executed:

M02
M30
END PGM

You can also change the

<name>.H.AFC.DEP file in the

Programming mode of operation. If necessary, you can even delete

a machining step (entire line) there.

In order to edit the

<name>.H.AFC.DEP file, you

might have to set the file manager so that all file
types are displayed (

SELECT TYPE soft key) Also see:

"Files", page 106

Activating/deactivating AFC

Select the

Program Run, Full Sequence operating

mode
Shift the soft-key row

To activate the adaptive feed control: Set the soft
key to

ON, and the TNC displays the AFC symbol

in the position display, See "Status displays",

page 75
To deactivate the adaptive feed control: Set the
soft key to

OFF