Using 3-d touch probes 15.6 – HEIDENHAIN TNC 640 (34059x-04) ISO programming User Manual
Page 483
Advertising

Using 3-D touch probes
15.6
15
TNC 640 | User's Manual for DIN/ISO Programming | 3/2014
483
You can also use all manual touch probe cycles,
except the corner probing cycle, in Turning mode.
Observe that in Turning mode all measured data
in the X coordinate are calculated and displayed as
diameter values.
To use the touch probe in Turning mode you should
separately calibrate the touch probe in Turning mode.
Because the basic setting of the turning spindle in
Milling mode and Turning mode may deviate, you
should calibrate the touch probe without center
offset. You can create additional tool data for this
purpose, e.g. as an indexed tool.
For more information about the touch probe table,
refer to the User’s Manual for Cycle Programming.
Advertising