Encoder and Gateway functionality, DPV0
53
5.6.11
Profile Version
Octets 24 and 25 of the diagnostic function provide the
PROFIBUS-DP encoder profile version that is implemented in the
device. The octet’s revision number and index are combined.
Example:
Profile version
1.40
Octet no.
24
25
Binary code.
00000001
01000000
Hex.
1
40
DDLM_Slave_Diag
Octet
24
25
Bits
15-8
7-0
Data
2
7
-2
0
2
7
-2
0
Revision number
Index
Profile Version
Table 31
Diagnostics, profile version
5.6.12
Software Version
Octets 26 and 27 of the DDLM_Slave_Diag function provide the
software version of the device. The octet’s revision number and
index are combined.
Example:
Software version
1.40
Octet no.
26
27
Binary code.
00000001
01000000