Elevator (accumulator) with 100 stop positions – Emerson FM-3 User Manual

Page 149

Advertising
background image

135

Programming

Punch a Hole in a Web a Specified Distance Beyond a Registration Mark

Description: Index a web to a position 2 inches beyond a registration mark. Then fire a solenoid
to punch a hole in the web. Wait for a sensor to indicate that the punch is in the down position.
Retract the solenoid. Wait until it is sensed in the up position.

Do While (TRUE)

‘Repeat until the program is halted

Index.0.Initiate

‘Registra-

tion,Offet=2.0in,Dist=20in,Vel=20in/s

Wait For InPosn

ModuleOutput.1=ON

‘Fire the punch solenoid

Wait For ModuleInput.2=ON

‘Wait for the “down” indicator

ModuleOutput.1=OFF

‘Retract the punch solenoid

Wait For ModuleInput.3=ON

‘Wait for the “up” indicator

Loop

Registration Index to Place a Product on a Conveyor After Each Lug

Registration Index (synchronized) to find the front edge of product, wait for input from a lug
sensor and repeat.

Do While (TRUE)

‘Repeat until the program is halted

Index.0.Initiate

‘Sync,Registration,Offset=0.500,

‘Dist=50.000,Vel=1.000in/in

‘Registration move to product sensor.

‘Go to head of next product.

Wait For Index.AnyCommandComplete

Wait For ModuleInput.2=ON

‘Wait for lug sensor on master conveyor.

Loop

Elevator (Accumulator) with 100 Stop Positions

Home, when an input goes on move down to the next position. When the bottom position is
reached, move back to home when the input goes on.

Home.0.Initiate

‘Sensor,Offset=0.00mm,Vel=100mm/s

Do While (TRUE)

‘Repeat until the program is halted

For Count = 2 To 100

‘Step to positions 2 - 100

Wait For ModuleInput.2=ON‘Wait for “Go”

input

Index.2.Initiate‘Incre-

metal,Dist=2.00mm,Vel=100mm/s

Wait For InPosn

Next

Wait For ModuleInput.2=ON

‘Wait for “Go” input

Index.1.Initiate

‘Absolute,Posn=0.00mm,Vel=1000mm/s

Wait For InPosn

Loop