Setting Up Parameters

Foldback RMS

This parameter accurately models the thermal heating and cooling of the drive and motor.
When it reaches 100 percent, current foldback will be activated. See the Diagnostics section
for an explanation of foldback.

Shunt Power RMS

This parameter models the thermal heating and cooling of the drive internal shunt. This
parameter indicates the percent of shunt capacity utilization. When this value reaches 100
percent, the drive will generate an RMS Shunt Power Fault. This parameter is not applicable
to the EN-204 which does not have an internal shunt resistor. This parameter is applicable to
the EN-208 and EN-214.

Information Tab (Online Only)

Drive Information Group

Firmware Part Number

Displays the part number of the drive firmware you are using.

Firmware Revision

Displays the revision of the drive firmware you are using.

Serial Number

Displays the serial number of the drive with which you are currently online.

Module Information Group

Firmware Part Number

Displays the part number of the FM-3 firmware you are using.

Firmware Revision

Displays the revision of the firmware in the FM-3 module with which you are currently
online.

Serial Number

Displays the serial number of the FM-3 module with which you are currently online.