5.2 Measurement Channels

The measured values of the inverter are shown on the display in the measurement channels. In
addition, you can read out a variety of measurement channels and messages from the inverter using
special communication devices (e.g. Sunny WebBox) or a PC with the relevant software
(e.g. Sunny Explorer).

Measurement channel

Explanation

Balancer

Operating mode set via "Power Balancer" parameter

CO2 saved

Amount of CO

2

saved during the operating time

E-total

Total energy yield

Error

Description of fault

Event-Cnt

Number of events

Fac

Power frequency

Grid Type

Type of power distribution grid to which the inverter is connected

h-on

Total operating hours

h-Total

Total number of operating hours in feed-in operation

I-dif

Residual current

Iac

Line current

Inv.TmpVal

Temperature measured at IGBT module

Ipv

DC input current

Max Vpv

Maximum DC input voltage

Mode

Current operating mode

Pac

Power fed into the power distribution grid

Pcb.Tmp.Val

Temperature measured at printed circuit board

Power On

Total system start-up counter

Riso

Insulation resistance of the PV plant before connecting to the power
distribution grid

Serial Number

Inverter serial number

Vac

Line voltage L1 - L2

Vac L1

Line voltage L1 - N

Vac L2

Line voltage L2 - N

Vpv

DC Input voltage

Vpv Setpoint

MPP tracking DC target voltage