SMA BEAM-BT-11 User Manual
Page 73

SMA Solar Technology AG
Troubleshooting
User Manual
BeamBT11-BA-BEN112713
73
The Sunny Beam lists
your inverters as well
as other inverters from
other plants
A different Bluetooth plant within the
radio range of the Sunny Beam uses
the same NetID as your Bluetooth
plant.
• Detect a free NetID for your
plant using Sunny Explorer
(see Sunny Explorer help).
• Set the NetID of your plant for
all devices of the plant (except
for Sunny Beam and
Sunny Explorer).
Connection quality of
the Sunny Beam is not
at least "good"
Sunny Beam is too far away from
the plant or the wireless connection
is disturbed. The cause of the
interference could be walls or
ceilings that excessively weaken the
waves used for wireless
transmission.
• Place the Sunny Beam closer
to a device of your plant. If this
is not possible, use the
SMA Bluetooth Repeater or
the SMA Bluetooth
Piggy-Back Plus to bridge the
radio gap.
Problem
Cause
Rectification