8 technical data, 1 pv generator connection data, Technical data – SMA SB 1100LV User Manual
Page 35: Pv generator connection data
Advertising

SMA
Technologie AG
Technical data
Installation Guide
SB1100LV-11:SE2006
Page 35
8 Technical data
8.1 PV generator connection data
Description
Unit
Setting
Max. input open circuit voltage
U
PV 0
60 V
(based on -10°C cell temperature)
Input voltage, MPP range
U
PV
21 V ... 60 V
Max. input current
I
PV max
62 A
Max. input power
P
DC
1240 W
Recommended total generator
power
1380 Wp (for central Europe)
Connection of the DC input side
DC screw terminal
Surge voltage protection
Thermally monitored varistors
Voltage ripple
U
ss
< 10% of the input voltage
Insulation protection
Ground fault monitoring (Riso > 1 MΩ)
Operating consumption
< 4 W (standby)
Reverse polarity protection
via short circuit diode