9.3.2 Checking the Function of the Varistors

Varistors are wear parts. Their functional efficiency diminishes with age or repeated strain as a result
of overvoltages. It is therefore possible that one of the thermally monitored varistors has lost its
protective function.

You can check the function of the varistors as follows:

1. Open the inverter as described in Section 7.2 "Opening the Inverter" (page 48).
2. Use a multimeter to check that in each of the

installed varistors there is a conductive connection
between terminals B and C.

Position of the varistors
The position of the varistors can be located with the help of the diagram below. Note the
following assignment of the terminals:

• Terminal A: outer terminal

(varistor connection with crimp)

• Terminal B: middle terminal
• Terminal C: outer terminal

(varistor connection without crimp)

Result

What to do

There is a conductive connection.

There is presumably a different error in the inverter.

1. Close the inverter as described in Section

7.3 "Closing the Inverter" (page 50).

2. Contact the SMA Service Line.