6 using the copy function – Yaskawa JVOP-181 USB Copy Unit User Manual

Page 17

Advertising
background image

6 Using the Copy Function

YASKAWA ELECTRIC

TOBP C730600 25D JVOP-181 Technical Manual

17

rdEr

Error reading data

<5>

rEAd

Reading parameter settings (flashing)

vAEr

Voltage class and/or unit capacity does not
match

<1>

vFyE

Parameter settings in the unit and those
saved to the option are not the same

vrFy

Comparing parameter settings (flashing)

<1> Parameters can only be copied to a unit when the power

supply specifications, capacity, control mode, and software

version match.

<2> Press and hold the Copy button for one second. The option

will copy parameter settings previously saved to the option to

the unit.

<3> Replace the option.

<4> Connect the option to a unit with the proper parameter

settings and press and hold the Read button for one second.

The option will then save the settings from the unit.

<5> Press and hold the Read button for one second. The option

will save the settings from the unit.

Display

Description