4 option components, Di-101 option, Option terminal block tb1 – Yaskawa 120 Vac Digital Input User Manual

Page 9: Ng. (refer to, Figure 1, For mor, 4option components

Advertising
background image

YASKAWA TOEP YEAOPT 07 A1000 Option DI-101 120 Vac Interface Installation Manual

9

4 Option Components

4

Option Components

DI-101 Option

Figure 1

Figure 1 DI-101 Option

Option Terminal Block TB1

An 10-position terminal block is provided for the connection of 120 Vac and common signal

control wires.

Table 2 Option Terminal Functions

A – DI-101 120 V Interface Card
B – Option terminals (to drive)
C – Option terminal block (to control wiring)

Terminal Functions

DI-101 Option Terminal Block Terminal

Signal Function

Description

Signal

Level

S1

Forward Run / Stop

<1>

<1> Terminal functions S1 to S8 may change based on drive programming.

Forward Run when closed,
stop when open (H1-01)

120 Vac
±10 %

S2

Reverse Run / Stop

<1>

Reverse Run when closed,
stop when open (H1-02)

S3

Multi-function Input

<1>

Multi-function contact inputs

(H1-03 to H1-08)

S4

Multi-function Input

<1>

S5

Multi-function Input

<1>

S6

Multi-function Input

<1>

S7

Multi-function Input

<1>

S8

Multi-function Input

<1>

X2

Common

Control Input Common

X2

Common (spare)

Control Input Common

A

B

C

Advertising